Pressure regulator
1 - suspension high pressure connection, 2 - high pressure circuit deaerator, 3 - brake system connection
Elements of the hydropneumatic rear suspension (power unit 4x4)
1 - LHM fluid tank, 2 - cover, 3, 4 - filter, 5 - filler plug, 6 - pointer, 7 - tank, 8 - pressure sensor, 9 - connection, 10 - heat shield, 11 - connector, 12 - sensor level, 13 - stabilizer, 14 - pressure regulator, 15 - deaerator, 16 - high and low pressure connections, 17 - liquid outlet pipeline, 18 - liquid outlet pipeline from suspension cylinders, 19, 20 - pump assembly
The deaerator is located on the pressure regulator.
1. Connect the bleed tank to the regulator deaerator.
2. Open deaerator.
3. Connect the free terminals of the connector next to the button for setting the suspension to the upper position using the switch.
4. Connect the high pressure pump power connector.
5. When the oil begins to flow into the container without air bubbles, you should close the deaerator, correctly (as for normal operation) connect the connectors, replenish the amount of LHM liquid to the required level.