Remove the following parts:
- air deflector (4);
- air resonator (5);
- bolt (2);
- air intake connecting element (3).

Disconnect the camshaft position sensor electrical connector (in area "a").
Release the fasteners in area "b".
Note: When removing, use a rag to protect the equipment from oil leaking from the hole.
Unscrew the bolts (6) and remove the sensor (1).

Caution: When reusing the sensor, replace the gasket.
Note: Clean the sensor installation area and check for any impact or scratch marks.
Install the parts in reverse order.
Tightening torque of sensor mounting bolts: 8 Nm.