Release and move the damper actuator (forward).
Disconnect the connector in the area «A».
Remove the bolt (1) and remove the camshaft position sensor (2).
Installing a Reusable Sensor
Install the right fixture (e.g. drill) diameter 7.5 mm (in the zone «b»).
Install the camshaft sensor (2) on a drill with a diameter of 7.5 mm. tighten bolt (1) torque 6 Nm.
Connect the socket in the zone «A».
Installing a new sensor
Install the right fixture (e.g. drill) diameter 7.5 mm (in the zone «b»).
Install the camshaft position sensor (2), to touch the target (camshaft sprockets).
tighten bolt (1) torque 6 Nm.
Connect the socket in the zone «A».