The injectors allow you to dose the amount of fuel (manufacturer "Siemens VDO").
The injectors operate with each electrical pulse. The injectors are individually controlled in the injection sequence (1-3-4-2) immediately before the intake phase. The fuel is sprayed under pressure at the inlet to the valve seat.
- Injector supply voltage: 12 V.
- Resistance: 12 Ohm.
- Consumption (static): 135±4 g/min.
- Consumption (dynamic): 4.9±0.2 mg/cycle.
Contact assignment:
- No. 1 - Management (+);
- No. 2 - Management (-).
The table below shows an example of how injection timing changes depending on engine mode when the accelerator pedal is pressed to maximum.
Changing injection time